Home/Green Bay/Reference Thermometer Calibration
Accredited Calibration

Reference Thermometer Calibration in Green Bay

ISO/IEC 17025 accredited reference thermometer calibration in Green Bay. NIST-traceable results, documented uncertainty, and ITS-90 referenced measurement — delivered with a 5-day standard turnaround.

StandardISO/IEC 17025
TraceabilityNIST
LocationGreen Bay
Reference Service
ISO 17025
NIST Traceable
5D Turnaround
Service Overview

Reference Thermometer Calibration

DOC REF: TCS-SVC-REF
Reference Thermometer Calibration reference

Reference thermometer calibration is the process of verifying and adjusting the accuracy of thermometers designated as reference standards within a calibration hierarchy. These instruments—including standard platinum resistance thermometers (SPRTs), precision digital thermometers, and liquid-in-glass reference thermometers—serve as the benchmarks against which working-level sensors and probes are compared. Calibration is performed by measuring the reference thermometer's response at defined temperature points and comparing those readings against primary standards traceable to the National Institute of Standards and Technology (NIST).

The accuracy requirements for reference thermometers are significantly tighter than for working instruments. Under ISO/IEC 17025 accreditation, reference thermometers used to standardize or calibrate working thermometers must have estimated measurement uncertainties that are less than or equal to one-half the specified tolerance of the instruments they verify, maintaining a minimum test uncertainty ratio (TUR) of 2:1. This level of metrological rigor ensures that the entire temperature measurement chain—from primary standard down to field instrument—remains accurate and defensible under audit.

01
Service
Reference Thermometer Calibration
02
Location
Green Bay
03
Accreditation
ISO/IEC 17025 · A2LA
04
Traceability
NIST · ITS-90
05
Turnaround
5-Day Standard
Technical Detail

Process, Standards & Applications

DOC REF: TCS-SVC-TECH

The Reference Thermometer Calibration Process

Step 1: Instrument Receipt and Preliminary Assessment

Each reference thermometer is inspected upon receipt for physical damage, contamination, or drift indicators. Previous calibration certificates are reviewed to establish historical performance trends. Serial numbers, model specifications, and the customer's required calibration range are documented in a laboratory information management system (LIMS) maintained under ISO/IEC 17025 protocols.

Step 2: Thermal Stabilization and Environmental Control

The reference thermometer and an accredited primary standard are placed into a precision temperature source—either a fixed-point cell, a stirred liquid bath, or a dry-well calibrator depending on the instrument type and required uncertainty. Environmental factors including ambient temperature, humidity, and airflow are controlled according to ISO/IEC 17025 requirements. Both instruments are allowed to reach full thermal equilibrium at each calibration point before any measurements are recorded.

Step 3: Multi-Point Comparison Measurement

Readings from the unit under test and the NIST-traceable primary standard are recorded simultaneously at each defined temperature point. A minimum of three to five test points spanning the instrument's operational range is standard practice. Deviations between the reference thermometer and the primary standard are calculated at each point, and measurement uncertainty is evaluated in accordance with the Guide to the Expression of Uncertainty in Measurement (GUM).

Step 4: Data Analysis and Certificate Issuance

All measurement data is analyzed for linearity, hysteresis, and repeatability. Corrections and expanded uncertainties are documented on an ISO/IEC 17025 accredited calibration certificate that includes traceability information, environmental conditions during testing, and the identity of the primary standards used. Certificates are issued with full NIST traceability and bear the accreditation body's mark.

Compliance & Standards

Reference thermometer calibration is governed by a framework of international and national standards that ensure measurement accuracy and traceability. ISO/IEC 17025:2017 establishes the general requirements for the competence of calibration laboratories, mandating documented traceability, validated methods, staff competency verification, and ongoing quality assurance of calibration data. Accreditation under ISO/IEC 17025 is assessed by bodies such as the American Association for Laboratory Accreditation (A2LA), providing independent verification that a laboratory's technical operations meet international benchmarks.

The International Temperature Scale of 1990 (ITS-90) defines the temperature scale used worldwide for precision thermometry, specifying the fixed-point temperatures and interpolation equations used to calibrate SPRTs from 13.8033 K to 1234.93 K. ASTM E2623 provides the standard practice for reporting thermometer calibrations, while ASTM E2877 establishes requirements for digital contact thermometer documentation and sensor conformance. NIST traceability ensures that all measurement results link back to the SI unit of temperature through an unbroken chain of comparisons with stated uncertainties. For regulated industries, compliance with 21 CFR Part 211 (pharmaceutical) and AS9100 (aerospace) requires that reference thermometers are calibrated at defined intervals using accredited, traceable methods.

Industry Applications

Reference thermometer calibration is essential across industries where temperature measurement accuracy directly impacts product quality, safety, and regulatory compliance. In pharmaceutical manufacturing, calibrated reference thermometers verify the sensors used in drug production, cold chain storage, and vaccine distribution, supporting compliance with FDA 21 CFR Part 211 and Good Manufacturing Practice (GMP) requirements. Aerospace and defense operations rely on reference-grade temperature standards to validate thermal testing of components and systems under extreme conditions, as required by AS9100 quality management standards.

Semiconductor fabrication demands reference thermometer calibration to maintain the tight thermal tolerances required in cleanroom environments and wafer processing equipment. In the food and beverage industry, HACCP protocols and USDA regulations require traceable temperature verification throughout production, storage, and transport. Petrochemical and energy sector operations use calibrated reference thermometers to verify process temperature instrumentation in refineries and power generation facilities. National metrology institutes and accredited calibration laboratories depend on reference thermometer calibration to maintain their own measurement standards and disseminate traceability to customer instruments throughout the calibration hierarchy.

Instrument Coverage

Supported Instrument Variants

DOC REF: TCS-SVC-INST

SPRT Calibration

Standard platinum resistance thermometer (SPRT) calibration is performed using ITS-90 fixed-point cells containing ultra-high-purity materials (99.9999% or greater) that produce precisely known phase-transition temperatures. SPRTs are the defining interpolation instruments of the ITS-90, covering the range from the triple point of argon at -189.3442 °C to the freezing point of silver at 961.78 °C. Calibration at fixed points—including the triple point of water (0.01 °C), the freezing point of tin (231.928 °C), the freezing point of zinc (419.527 °C), and the freezing point of aluminum (660.323 °C)—provides uncertainties within ±0.001 °C.

Each SPRT is calibrated at combinations of fixed points corresponding to the desired ITS-90 subrange. Resistance measurements are taken using precision AC or DC resistance bridges referenced to calibrated standard resistors. The ratio of the SPRT's resistance at each fixed point to its resistance at the triple point of water (W value) is used to derive the ITS-90 deviation function coefficients unique to that thermometer. Calibration results are documented on an ISO/IEC 17025 accredited certificate with full NIST traceability.

Precision Digital Reference Thermometer Calibration

Precision digital reference thermometers are high-resolution instruments used as transfer standards in calibration laboratories and quality control environments. These instruments typically feature resolutions of 0.001 °C to 0.01 °C and system accuracies ranging from ±0.015 °C to ±0.05 °C, making them suitable for verifying working-level temperature sensors and probes. Calibration is performed by comparing the digital reference thermometer against a NIST-traceable primary standard at multiple temperature points spanning the instrument's operational range.

The calibration process involves stabilizing both the unit under test and the primary standard in a precision stirred liquid bath or dry-well calibrator. Readings are recorded simultaneously at a minimum of three to five test points, and deviations are calculated with associated measurement uncertainties. Calibration certificates are issued from an ISO/IEC 17025:2017 accredited laboratory, individually numbered and linked to the specific probe and readout combination tested. Annual recalibration is recommended to maintain accuracy within manufacturer specifications and regulatory requirements.

Additional Variants Supported

  • · secondary standard PRT calibration
  • · liquid-in-glass reference thermometer calibration
  • · spirit-filled reference thermometer calibration
  • · Galinstan reference thermometer calibration
  • · precision thermistor reference thermometer calibration
  • · long-stem quartz-sheath SPRT calibration
  • · metal-sheath SPRT calibration
  • · glass capsule SPRT calibration
  • · high-temperature SPRT calibration
  • · working standard SPRT calibration
Local Context

Green Bay Industry Demand

DOC REF: TCS-SVC-GEO

Temperature Calibration Demand in Green Bay, WI

Green Bay is a major hub for food processing and packaging manufacturing in northeastern Wisconsin, creating strong demand for precise temperature calibration services. Schreiber Foods, headquartered in Green Bay with over 10,000 employees, operates large-scale dairy manufacturing lines where pasteurization and cold storage temperatures are monitored continuously. American Foods Group, a family-owned beef processor established in 1946, relies on calibrated temperature instrumentation throughout its slaughter and processing operations to ensure product safety. BelGioioso Cheese, also based in Green Bay, produces Italian specialty cheeses requiring strict adherence to aging and storage temperature specifications.

Beyond food processing, Green Bay Packaging operates one of the most modern recycled paper mills in the world at its Green Bay Mill Division. Industrial drying, coating, and curing processes at the facility demand accurately calibrated temperature sensors to maintain product consistency and energy efficiency. Schwabe North America, a pharmaceutical manufacturer located in Green Bay, is subject to stringent temperature validation requirements across production and storage environments.

Local Compliance Requirements

Food processing facilities in Green Bay are regulated under the FDA Food Safety Modernization Act (FSMA) and 21 CFR Part 117, which mandate documented preventive controls including temperature monitoring at critical control points. Wisconsin has adopted the 2013 FDA Food Code through the Wisconsin Department of Agriculture, Trade and Consumer Protection (DATCP), requiring licensed food establishments to maintain calibrated thermometers and verifiable temperature records. The Brown County Environmental Health Unit enforces these standards through routine facility inspections.

  • USDA FSIS regulations require continuous temperature monitoring in meat and poultry processing facilities such as those operated by American Foods Group
  • ISO/IEC 17025 accredited calibration ensures measurement traceability to NIST standards, satisfying audit requirements under FDA 21 CFR Part 117 and FSMA
  • OSHA process safety management standards apply to industrial operations where temperature excursions pose worker safety risks
  • Pharmaceutical manufacturing at facilities like Schwabe North America requires temperature instrument calibration compliant with FDA 21 CFR Parts 210 and 211
Related Services

Other Calibration in Green Bay

DOC REF: TCS-SVC-XREF